DESCRIPTION: Battery Disconnect Switch
APPLICATIONS: A non-fused current interrupt disconnect designed for opening the circuit between a battery and the complete electrical load of a battery-powered system.
RATING: 400A continuous,. 50Vac/Vdc. Vehicle cranking and max. surge currents to 2000A (based on 20% duty cycle with ON times of 5 seconds max.).
TEMPERATURE RATING: –40°F (–40°C) to 150°F (65°C).
BRANCH CIRCUIT PROTECTION: 2.5kA @ 12Vdc (Series 121 & 124 -01 sealed & Series 123 w/plastic cover)
TERMINATION: 1/2-13 Copper alloy stud.
TORQUE RATING: 420 in-lbs (47.5Ntm) max.
MOUNTING TORQUE RATING: With mounting brackets: 48 in-lbs (5.4Ntm) max; without mounting brackets: 10 in-lbs (1.1Ntm) max.